Psig Max
![]() |
![]() 20380 NEW Dixon R30 06R Regulator 300 Psig Max US $109.46
|
![]() Airgas Compressed Gas Regulator 360 4 580 V max 3000 PSIG NEW Nitrogen and inert US $102.50
|
![]() Pneumotive 100 PSIG Max Air Compressor US $100.00
|
![]() Fairchild Ashcroft 30222 Model 30 Pressure Regulator 250 PSIG Max 0 10 Rang US $34.30
|
![]() BOSTON GEAR LUBRICATOR EN43340 INLET 150PSIG MAX US $32.00
|
![]() Norgren Lubricator L12 600 0PGA 250 psig max US $30.00
|
![]() REGO 1682M PNEUMATIC REGULATOR MAX 400 PSIG US $25.95
|
![]() NORGREN LUBRICATOR L12 200 0PYA 250 PSIG 175F MAX US $25.00
|
![]() Wilkerson Pressure Regulator R10 02 Q87 Max 300 PSIG US $25.00
|
![]() NEW NORGREN LUBRICATOR L07 200 MPAA 150 PSIG 125F MAX L07200MPAA US $23.95
|
![]() NORGREN LUBRICATOR L12 300 MPNA 150 PSIG 125F MAX US $20.00
|
![]() NORGREN LUBRICATOR 4962K23 150 PSIG 125F MAX US $20.00
|
![]() Schrader Bellows Lubricator 17L31BCSB 150 PSIG Max Temp 1250 Deg F US $20.00
|
![]() Fairchild Air Regulator 30242 Max PSIG 250 US $20.00
|
![]() AMFLO 2010A INLET 150 PSIG MAX TEMP 125F MAX US $19.99
|
![]() NEW SPEEDAIRE 2Z766C 1 4 FILTER 150 MAX PSIG US $15.00
|
internal P & T for compressors?
Hello,
I have a 5hp compressor and I understand the max pressure is 175 psig but there is probably a higher instantaneous pressure in the head due to piston velocity before the valves open. I was hoping someone had some documentation on what those numbers might be and how much higher they are than the max of 175. I need to make sure my application is safe.
Thanks!
The internal pressure of a compressor is dependent on the pressure drop across the discharge valves. That pressure drop varies depending on the type of valve, the fluid being compressed and other variables. Only the compressor manufacturer can provide you with the kind of information you are looking for.
There is another factor that enters into the internal pressure of a compressor. It is caused by the pulsations generated by the compressor and these pulsations can actually produce a standing wave with pressures much higher than the pressure indicated at the discharge. Southwest Research Institute in San Antonio, Tx has a great deal of information and experience with this type of problem.
You also need to know if the 175 psi is a pressure limit or if it is possible that you can exceed the mechanical limits of the compressor at pressures below the 175 psi. This type of failure is usually tied to a rating known as "rod load".